Print Back
Barnes 3SE series horizontal discharge submersible non-clog pumps feature heavy-duty, cast-iron construction with stainless steel hardware. Double-seal units are equipped with temperature sensors and moisture sensors as standard for connection to relay(s) in control panel. Oversized ball bearings are designed for more than maximum pump loads, and are lubricated for the life of the pump.
  • 3 in. (75 mm) horizontal discharge sizes
  • Spherical solids up to 2-1/2 in. (65 mm)
  • Motor sizes from .75 hp (.6 kW) to 3 hp (2.2 kW)
  • Enclosed impellers
  • Concentric volutes
  • Explosion-proof motors meet Class I, Groups C & D, Division I design criteria.
  • Capacities to 370 gpm (84 m³/h)
  • Heads to 35ft. (11 m)
Available with mechanical seal.
Unit of Measure

Specifications

Manufacturer

N/A
Barnes

Pump Classification

N/A Non-Clog Pumps

Series

N/A 3SE

Discharge

N/A 3 in75 mm

Motor Power

N/A 1 hp0.75 kW

Impeller Design

N/A Enclosed

Volutes Design

N/A Concentric

Max. Capacity

N/A 370 gpm84 m³/h

Max. Head

N/A 35 ft11 m

Speed

N/A 3450 rpm

Electrical Rating

N/A 230V 1ph (1750 RPM only) 230V 3ph 460V 3ph 575V 3ph

Cord Length

N/A 25 ft

Construction

N/A Cast Iron

Impellers Material

N/A Cast Iron

Max. Solids

N/A 1.5 in38 mm

Operation

N/A Manual

Applications

N/A

  • Sump is outside of the building and no above-ground appendage is practical.
  • Overhead clearance is not sufficient to allow for standard vertical column units, such as stairways, underground tunnels, underpasses, etc.
  • Power failures may cause flooding of pump chamber, damaging standard open-type motors.